Showing 23351–23400 of 23686 results

Thiết bị Siemens khác

3VA1216-5MH32-0AA0

circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, starter protection TM120M, AM, In=160A without overload protection short-circuit protection Ii=7…16 x In nut keeper kit

3VA1220-4EF32-0AA0

circuit breaker 3VA1 IEC frame 250 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=200A overload protection Ir=140A…200A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1220-5EF32-0AA0

circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=200A overload protection Ir=140A…200A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1220-6EF32-0AA0

circuit breaker 3VA1 IEC frame 250 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM240, ATAM, In=200A overload protection Ir=140A…200A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1225-4EF32-0AA0

circuit breaker 3VA1 IEC frame 250 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM240, ATAM, In=250A overload protection Ir=175A…250A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1225-5EF32-0AA0

circuit breaker 3VA1 IEC frame 250 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=250A overload protection Ir=175A…250A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1340-5EF32-0AA0

circuit breaker 3VA1 IEC frame 400 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=400A overload protection Ir=280A…400A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1112-5ED32-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

3VA1112-5ED36-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In clamp connection

3VA1112-5EF32-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A…125A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1112-6EE36-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 3-pole, line protection TM220, ATFM, In=125A overload protection Ir=88A…125A short-circuit protection Ii=10 x In clamp connection

3VA1112-6EF42-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class H Icu=70kA @ 415V 4-pole, line protection TM240, ATAM, In=125A overload protection Ir=88A…125A short-circuit protection Ii=5…10 x In N conductor unprotected nut keeper kit

3VA1116-5ED32-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=160A overload protection Ir=160A fixed short-circuit protection Ii=10 x In nut keeper kit

3VA1116-5EF32-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM240, ATAM, In=160A overload protection Ir=112A…160A short-circuit protection Ii=5…10 x In nut keeper kit

3VA1125-4ED26-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 2-pole, line protection TM210, FTFM, In=25A overload protection Ir=25A fixed short-circuit protection Ii=12.8 x In clamp connection

3UG4615-1CR20

!!! product phase-out !!! The preferred successor type is 3UG5616-1CR20 phase sequence phase failure 3×160-690 V screw digital monitoring relay for 3-phase supply voltage connectable phase sequence phase failure 3 x 160 to 690 V 50 to 60 Hz AC undervoltage and overvoltage 160-690 V hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax screw terminal

3UG4616-1CR20

!!! product phase-out !!! The preferred successor type is 3UG5616-1CR20 phase sequence phase failure 3×160-690 V screw digital monitoring relay for 3-phase voltage with N-conductor connectable phase sequence phase failure 3 x 90 to 400 V 50 to 60 Hz AC undervoltage and overvoltage 90-400 V hysteresis 1-20 V 0-20 s each for Umin and Umax 1 CO for Umin 1 CO for Umax screw terminal

3UG4618-1CR20

!!! product phase-out !!! The preferred successor type is 3UG5618-1CR20 phase sequence phase failure 3×160-690 V screw digital monitoring relay for 3-phase voltage with N-conductor automatic phase sequence correction phase failure 3 x 90 to 400 V 50 to 60 Hz AC undervoltage and overvoltage 90-400 V hysteresis 1-20 V OFF delay 0-20 s asymmetry 0-20% 1 CO for phase correction 1 CO for power system faults screw terminal

3UG4622-1AA30

Digital monitoring relay Current monitoring, 22.5 mm from 0.05-10 A AC/DC 0vershoot and undershoot Supply voltage: 24 V AC/DC 50 to 60 Hz DC and AC without galvanic isolation to measuring circuit ON delay and noise pulses delay 0.1 to 20 s Hysteresis 0.01 to 5 A 1 change-over contact with or without fault buffer screw terminal Successor product for 3UG3522-1AC..

3UG4625-1CW30

Digital monitoring relay for residual current monitoring (with current transformer 3UL23) Setting range 0.03…40 A separate for warning threshold and switch-off value supply voltage 24 … 240 V AC/DC, 50 .. 60Hz ON delay and tripping delay 0.1 to 20 s Shutdown hysteresis up to 50% Warning hysteresis 5% fixed Width 22.5 mm, 2 change-over contacts with or without fault buffer screw terminal

3UG4633-1AL30

Digital monitoring relay Voltage monitoring, 22.5 mm from 17-275 V AC/DC Overshoot and undershoot Self-powered Spike delay 0.1 to 20 s Hysteresis 0.1 to 150 V 1 CO contact With or without error buffer Screw terminals Successor product for 3UG3534, 3UG3535

3UL2303-1A

Residual-current transformer for residual current monitoring Bushing opening 55 mm Residual current 30 mA…40 A

3VA1010-4ED32-0AA0

circuit breaker 3VA1 IEC frame 100 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In nut keeper kit

3VA1020-2ED36-0AA0

circuit breaker 3VA1 IEC frame 100 breaking capacity class B Icu=16kA @ 415V 3-pole, line protection TM210, FTFM, In=20A overload protection Ir=20A fixed short-circuit protection Ii=16 x In clamp connection

3VA1025-2ED36-0AA0

circuit breaker 3VA1 IEC frame 100 breaking capacity class B Icu=16kA @ 415V 3-pole, line protection TM210, FTFM, In=25A overload protection Ir=25A fixed short-circuit protection Ii=12.8 x In clamp connection

3VA1025-4ED32-0AA0

circuit breaker 3VA1 IEC frame 100 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=25A overload protection Ir=25A fixed short-circuit protection Ii=12.8 x In nut keeper kit

3VA1032-3ED32-0AA0

circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=32A overload protection Ir=32A fixed short-circuit protection Ii=10 x In nut keeper kit

3VA1040-3ED32-0AA0

circuit breaker 3VA1 IEC frame 100 breaking capacity class N Icu=25kA @ 415V 3-pole, line protection TM210, FTFM, In=40A overload protection Ir=40A fixed short-circuit protection Ii=10 x In nut keeper kit

3VA1110-5ED32-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM210, FTFM, In=100A overload protection Ir=100A fixed short-circuit protection Ii=10 x In nut keeper kit

3VA1110-5EE32-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class M Icu=55kA @ 415V 3-pole, line protection TM220, ATFM, In=100A overload protection Ir=70A…100A short-circuit protection Ii=10 x In nut keeper kit

3VA1112-3ED42-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class N Icu=25kA @ 415V 4-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In N conductor unprotected nut keeper kit

3VA1112-4ED32-0AA0

circuit breaker 3VA1 IEC frame 160 breaking capacity class S Icu=36kA @ 415V 3-pole, line protection TM210, FTFM, In=125A overload protection Ir=125A fixed short-circuit protection Ii=10 x In nut keeper kit

3UF7101-1AA00-0

Current measuring module, Set current 2.4…25 A Overall width 45 mm, straight-through transformer

3UF7102-1AA00-0

Current measuring module, Set current 10…100 A Overall width 55 mm, straight-through transformer

3UG4511-1BN20

!!! product phase-out !!! The preferred successor type is 3UG5511-1BR20 phase sequence monitoring 3×160-260 V 2 CO analog monitoring relay phase sequence monitoring 3 x 160…260 V 50…60 Hz AC 2 changeover contacts screw terminal

3UG4582-1AW31

insulation monitoring relay for ungrounded (IT) networks up to 250 V AC, 15-400 Hz and up to 300 V DC measuring range 1-100 kohm supply voltage 24-240 V AC/DC 22.5 mm, 1 changeover contact screw terminal

3UG4583-1CW30

Insulation monitoring relay for ungrounded (IT) supply systems up to 400 V AC, 15-400 Hz and up to 600 V DC Measuring range 1-100 / 2-200 kohm Supply voltage 24-240 V AC/DC Width 45 mm 1 + 1 or 2 change-over contacts screw terminal

3SU1900-0BC31-0DA0

Backing plate round, for EMERGENCY STOP mushroom pushbutton, yellow, self-adhesive, Outer diameter 75 mm, inside diameter 23 mm, with inscription: EMERGENCY STOP

3SU1900-0BC31-0NB0

Backing plate round, for EMERGENCY STOP mushroom-type actuator, yellow, self-adhesive, outer diameter 75 mm, inside diameter 23 mm, with inscription: NOT-HALT, EMERGENCY STOP, EMERGENZA, EMERGENCIA 4 languages: DE,EN,IT,SP

3TG1010-0BB4

power relay, AC-3, 8.4 A, 4 kW / 400 V, 3-pole, 24 V DC, auxiliary contacts: 1 NO, screw terminal

3TH4244-0BB4

Contactor relay, 44E, DIN EN 50011, 4NO + 4NC, screw terminal DC operation 24 V DC

3TH4253-0AP0

Contactor relay, 53E, DIN EN 50011, 5NO + 3NC, screw terminal AC operation 230 V AC 50 Hz, 277 V 60 Hz

3TH4271-0BB4

Contactor relay, 71E, DIN EN 50011, 7 NO + 1 NC, screw terminal DC operation 24 V DC

3TH4280-0AP0

Contactor relay, 80E, DIN EN 50011, 8 NO, screw terminal AC operation 230 V AC 50 Hz, 277 V 60 Hz

3TH4310-0BM4

Contactor relay, 100E, EN 50011 10 NO, screw terminal, DC operation, 220 V DC

3TH4364-0BM4

Contactor relay, 64E, EN 50011, 6NO + 4NC, screw terminal, DC operation, 220 V DC

3TH4382-0BM4

Contactor relay, 82E, EN 50011, 8 NO + 2 NC, screw terminal, DC operation, 220 V DC

3UF7010-1AU00-0

Basic unit SIMOCODE pro V PB PROFIBUS DP interface 12 Mbit/s, RS 485, 4I/3O freely parameterizable, Us: 110…240 V AC/DC, input for thermistor connection Monostable relay outputs, expandable by extension modules

3SU1400-1AA10-1BA0

Contact module with 1 contact element, 1 NO, screw terminal, for front plate mounting, Minimum order quantity 5 or a multiple of this

3SU1400-1AA10-1CA0

Contact module with 1 contact element, 1 NC, screw terminal, for front plate mounting, Minimum order quantity 5 or a multiple of this